Please log in to access your Bock portal.

Lighting Requirements in Montgomery, Ohio

Lighting Regulations in Montgomery, Ohio: Balancing Historic Charm with Modern Illumination Needs

Introduction

Montgomery, Ohio stands as a testament to America's rich historical tapestry. Founded in 1795 and named after Revolutionary War hero General Richard Montgomery, this Hamilton County suburb has carefully preserved its historical character while evolving to meet modern needs. The city's approach to lighting regulations reflects this delicate balance—ensuring safety and functionality while protecting the community's aesthetic values and historical integrity.

As Montgomery has grown from a small settlement to a thriving suburban community near Cincinnati, its lighting regulations have evolved to maintain the city's unique character while providing adequate illumination for residents and businesses alike.



Quick Reference Guide: Essential Lighting Requirements

Before diving into the details, here's a quick overview of Montgomery's most critical lighting regulations:

  • Light Trespass Limits: Maximum spillage onto adjacent properties must not exceed .01 footcandles at any point five feet from the property line
  • Pole Height Restrictions:
  • 20 feet maximum in residential districts and OM Core District
  • 25 feet maximum in Office (O) and Business (LB, GB, OM Outer) Districts
  • Fixture Requirements: All light poles must use luminaires with a 90-degree full cutoff with a flat lens
  • Permitted Lamp Types: High pressure sodium, metal halide, or LED
  • Prohibited Lamp Types: Low pressure sodium and mercury vapor lamps


General Lighting Requirements

Directional Standards

All lighting in Montgomery must be arranged to direct light away from adjacent parcels and streets. The regulations specifically prohibit lighting that creates:

  • Excessive brightness
  • Glare hazardous to motorists
  • Conditions reasonably objectionable to adjacent property owners

When Lighting Should Be Used

The regulations specify that exterior lighting should be limited to what's needed for:

  • Illuminating parking areas
  • Pedestrian activity areas
  • Safety and security needs
  • Points of ingress and egress (as required by building codes)

Architectural Considerations

The Planning Commission, through site plan review, may permit limited exterior lighting on buildings to highlight architectural features. Additionally, lighting under canopies and awnings is permitted when covering sidewalks or entrances, provided the canopy or awning is opaque and the intent is not to illuminate the entire structure.



Illumination Levels for Different Districts and Uses

Montgomery's regulations include detailed specifications for maximum illumination levels across different districts and property uses.

Commercial and Office Districts

The following maximum average illumination levels (in footcandles/fc) apply to exterior areas:

Office, LB, GB, OM(Outer), OMG Districts:

  • Administrative/Professional Office: 2 fc
  • Medical Facilities (24-hour operation): 3 fc
  • Retail Stores, Shopping Centers: 2 fc
  • Restaurants, Bars, Nightclubs: 2 fc
  • Professional Services: 2 fc
  • Indoor Recreational/Entertainment: 2 fc

OM Core District:

  • Administrative/Professional Office: 1.5 fc
  • Medical Facilities (24-hour operation): 2 fc
  • Retail Stores, Shopping Centers: 1.5 fc
  • Restaurants, Bars, Nightclubs: 1.5 fc
  • Professional Services: 1.5 fc
  • Indoor Recreational/Entertainment: 1 fc

Specialized Uses

Gasoline Stations/Convenience Stores:

  • Under Canopy (within 15' of pump):
  • Day/Evening: 20 fc
  • Overnight: 5 fc
  • Balance of Vehicle Access/Parking:
  • Day/Evening: 5 fc
  • Overnight: 2 fc

Drive-Up Windows (within 10' of window):

  • Day/Evening: 10 fc
  • Overnight: 3 fc

Auto Dealerships:

  • Front Row Display:
  • Day/Evening: 25 fc (O, GB) / 10 fc (LB, OMG & OM)
  • Overnight: 10 fc (O, GB) / 5 fc (LB, OMG & OM)
  • Balance of Display Areas:
  • Day/Evening: 12 fc (O, GB) / 5 fc (LB, OMG & OM)
  • Overnight: 3 fc (all districts)

Restaurants with Outdoor Seating:

  • Day/Evening: 3 fc (all districts)
  • Overnight: 1 fc (all districts)

Note: "Overnight" typically begins one hour after close of business or 11:00 p.m., whichever is earlier. 24-hour operations may be exempt from overnight restrictions.



Residential Lighting Considerations

Permitted Residential Lighting

The regulations specifically address residential lighting needs:

  • Low-intensity residential lighting including porch lights and lawn lights are permitted in any yard
  • Light poles/fixtures not exceeding 8 feet in height are permitted
  • Fixtures must be redirected if they create glare for drivers on public roadways
  • Light poles/fixtures must be of commonly used material and design

Outdoor Activity Areas

For properties with outdoor activity areas with night lighting:

  • 100-foot setback required from any residential property
  • Night lighting approval depends on careful review of site characteristics and adjacent residential properties


Sign Illumination Requirements

Sign lighting in Montgomery is carefully regulated to maintain community character while ensuring visibility:

General Requirements

  • Light sources must be shielded from adjacent buildings and streets
  • Brightness must not cause glare hazardous to pedestrians/motorists
  • Exposed incandescent lamps must not exceed 25 watts unless screened or placed over 10 feet above ground

District-Specific Requirements

  • Residential Districts & Old Montgomery District: Only external illumination permitted
  • Old Montgomery Gateway District: Signs may be backlit or externally illuminated, but internal illumination is prohibited
  • Office & Commercial Business Districts: Signs may be illuminated internally or by reflected light, subject to specific requirements

Internally Illuminated Signs

When permitted, internally illuminated signs must:

  • Allow illumination of only letters, numbers, or identifying symbols
  • Prevent light from passing through the background
  • Use opaque, non-reflective material for the sign's exterior surface
  • Have matte-finish, non-reflective surfaces for plastic-faced signs


Technical Requirements for Light Fixtures

Fixture Specifications

The regulations include specific technical requirements for light fixtures:

  • Full Cutoff Requirement: All light poles must use luminaires with a 90-degree full cutoff with a flat lens
  • Wall-Mounted Fixtures: When using high intensity (HID) bulbs, fixtures must be housed in full cut-off fixtures mounted at 90 degrees from the ground
  • Visibility Restriction: Light sources must not be directly visible from five feet beyond the property line

Approved Light Sources

The regulations specify which types of lighting are permitted:

  • Permitted: High pressure sodium, metal halide, LED
  • Prohibited: Low pressure sodium, mercury vapor lamps
  • Special Considerations: Incandescent lighting and lighting produced by combustion of fossil fuels may be approved in certain contexts


What Property Owners Should Know

Planning for Compliance

When planning lighting for your property in Montgomery, consider these practical steps:

  • Documentation Requirements: Submit photometric plans showing maximum foot candles at the surface, light pole heights and locations, and average foot candle calculations
  • Design Considerations: Plan lighting that highlights architectural features appropriately while minimizing light trespass
  • Fixture Selection: Choose fixtures that meet the full cutoff requirements and use approved light sources
  • Height Planning: Ensure light poles do not exceed height restrictions for your district

Common Compliance Issues

Be aware of these frequently overlooked requirements:

  • Light Trespass: Light spillage onto neighboring properties is strictly limited
  • Lighting Hours: Some uses have different illumination level requirements for day/evening versus overnight
  • Fixture Design: The direction and containment of light is as important as its intensity


Supporting Montgomery's Lighting Vision

At Bock Lighting, we understand and appreciate Montgomery's commitment to preserving its historical character while providing modern lighting solutions. With roots in Northeast Ohio dating back to 1918, we share the community's values regarding historical preservation and aesthetic integrity.

Our understanding of regional architectural styles and lighting needs allows us to serve as a resource for property owners navigating Montgomery's detailed lighting requirements. We recognize the balance the city seeks to maintain between safety, functionality, and aesthetic preservation.

As a community partner, Bock Lighting is committed to supporting Montgomery's vision through education about lighting regulations and sustainable practices that respect the city's unique character. Our experience with projects that honor community standards makes us a valuable ally in maintaining Montgomery's cherished historical aesthetics.



Conclusion

Montgomery's lighting regulations reflect the city's thoughtful approach to balancing modern needs with historical preservation. By carefully controlling light levels, fixture designs, and illumination patterns, the city maintains its distinctive character while ensuring safety and functionality.

Property owners who understand and embrace these regulations contribute to the community's unified aesthetic vision—preserving Montgomery's historical charm while providing appropriate illumination for today's needs.

For specific questions about your property's lighting requirements, consult with the Montgomery Planning Commission or zoning officials who can provide guidance tailored to your unique situation.

Reach out to Bock